Features:
Active
power Factor Correction
Harmonic:
Meet EN61000-3-2 standards
Remote
DC Sense on +5V and +3.3V
Universal
Power Input
Short
Circuit Protection
Over
Current Protection
Over
Voltage Protection
Over
Power Protection
MTBF
>100,000 Hours
|
General
Specifications:
Input
Range: 100
to 240 VAC, +/-10%
Power
Factor: 0.95 minimum
Efficiency:
70% minimum, at full load
Hold
up Time: 20mS minimum, at full load
PSON
(Remote ON/OFF): TTL compatible signal
Power
Good: 100 to 500 ms, TTL compatible signal
Cooling
Fan: 60x60x25 mm
Operating
Temperature: 0 to 50 degree
Operating
Humidity: 20 to 90 %
EMI/RFI:
CE, FCC class B and CISPR class B
Safety:
UL, cUL, CB, TUV
|
Electrical
Specifications:
Regulation,
Ripple & Noise:
Output
|
+5V
|
+3.3V
|
+12V
|
-5V
|
-12V
|
5Vsb
|
Load
Regulation
|
ĄÓ
5%
|
ĄÓ
5%
|
ĄÓ
5%
|
ĄÓ
10%
|
ĄÓ
10%
|
ĄÓ
5%
|
Cross
Regulation
|
ĄÓ
5%
|
ĄÓ
5%
|
ĄÓ
5%
|
ĄÓ
10%
|
ĄÓ
10%
|
ĄÓ
5%
|
Line
Regulation
|
ĄÓ
1%
|
ĄÓ
1%
|
ĄÓ
1%
|
ĄÓ
1%
|
ĄÓ
1%
|
ĄÓ
1%
|
Ripple
& Noise
|
50mV
|
50mV
|
120mV
|
100mV
|
120mV
|
50mV
|
Input
and Output Ratings:
Input
|
Output
|
Voltage
|
Frequency
|
Current
|
Watt
|
Load
|
+5V
|
+3.3V
|
+12V1
|
+12V2
|
-5V
|
-12V
|
5VSB
|
100ĄV
240
VAC
|
47-63
Hz
|
8A
max
|
480W
|
Max
Load
|
30A
|
30A
|
18A
|
18A
|
0.3A
|
0.8A
|
2A
|
Min
Load
|
1A
|
0A
|
0.5A
|
0.5A
|
0A
|
0A
|
0A
|
Note:
1. The +12V1 & +12V2 combine output currents maximum are 30A.
2.
The +5 & +3.3 Volt combine total output shall not exceed 220W.
3.
The +5, +3.3 and +12 Volt combine total output shall not exceed 380W.
4.
Noise bandwidth is from DC to 20 MHz.
|